Building Codes, Listings and Project Requirements

We understand that it’s difficult to stay up to date with ever evolving building codes, listings and project requirements. Here, you can find out what building codes and listings our products meet and gather the necessary documentation for your project.  Simply browse through all of our listings, or click on the organization you are interested in the gray bar below.

UL Listings

NameUL CategoryCertified for CanadaRated For
Fire and Smoke Rated Rolling Doors without Egress
Rolling Fire DoorsRolling-Steel Type Fire Doors 4 hour, 3 hour, 1-1/2 hour, 1 hour or 3/4 hour
UL Control Number: GSVV.R1422
Canadian Control Number: GSVV7.R1422
SmokeShield Rolling Fire DoorsLeakage Rated Door Assemblies Leakage Rated
UL Control Number: OPBW.R1422
Firemiser Insulated Rolling Fire DoorsRolling-Steel Type Fire Doors 4 hour, 3 hour, 1-1/2 hour, 1 hour or 3/4 hour
UL Control Number: GSVV.R1422
Canadian Control Number: GSVV7.R1422
SmokeShield Insulated Rolling Fire DoorsLeakage Rated Door Assemblies Leakage Rated
UL Control Number: OPBW.R1422
Fire and Smoke Rated Counter Doors without Egress
Counter Fire Doors (Up to 12'W x 10'H)Service Counter Type Fire Doors 1-1/2 hour, 1 hour or 3/4 hour
UL Control Number: GSWT.R15854
Canadian Control Number: GSWT7.R15854
Counter Fire Doors (From 12'W x 10'H to 16'W x 7'6"H oversize)Rolling-Steel Type Fire Doors 3 hour, 1-1/2 hour, 1 hour or 3/4 hour
UL Control Number: GSVV.R1422
Canadian Control Number: GSVV7.R1422
SmokeShield Counter Fire DoorsLeakage Rated Door Assemblies Leakage Rated
UL Control Number: OPBW.R1422
Counter Fire Doors with Integral FrameService Counter Type Fire Doors1-1/2 hour, 1 hour or 3/4 hour
UL Control Number: GSWT.R15854
Canadian Control Number: GSWT7.R15854
Labeled Countertops Miscellaneous Fire Door Accessories1-1/2 hour
UL Control Number: GVUX.R15865
Canadian Control Number: GVUX7.R15865
Operators for Rolling Fire Doors
Retrofit Fire Door OperatorsRetrofit Rolling Steel Fire Door Operators Operator Classification
UL Control Number: GUNL.R22357
Canadian Control Number: GUNL7.R22357

Back to Top

Factory Mutual (FM)

The following documents are excerpts from the FM Approval Guide that list Cornell product. A complete FM Approval Guide is available through the Factory Mutual Website.

Back to Top

Wind Load Listings

Cornell Coiling, Thermiser Insulated Coiling and Fire doors can be configured to withstand the full range of specific wind load requirements including missile impact ratings. Specified wind load designs have been performance validated through third party testing to one or more of the following performance criteria:

  • ANSI/DASMA-108
  • ASTM E 330
  • Miami-Dade County test protocols TAS 201, TAS 202 and TAS 203
  • Florida Building Code (FBC)
  • Texas Department of Insurance (TDI)
  • Signed and Sealed Calculations

Miami-Dade County NOAs

Notice of ApprovalFlorida Building Code EditionProductSizeImpact SpeedLarge & Small
Missile Impact
PSF +/-High Velocity Hurricane ZoneExpiration Date
12-1019.272010Standard Service Door (ESD10)Up to 25'-5" Wide50 FPSX60XMay 30, 2018
13-0430.112010Insulated Service Door (ESD20 & ESD30)Up to 14'-5" Wide50 FPSX120XSeptember 18, 2018
13-0430.102010Insulated Service Door (ESD20 & ESD30)Up to 12'-5" Wide50 FPSX60XJuly 7, 2018
13-0430.112010Standard Service Door (ESD10)Up to 14'-5" Wide50 FPSX60XSeptember 18, 2018
12-1019.272010Insulated Service Door (ESD20 & ESD30)Up to 25'-5" Wide50 FPSX60XMay 30, 2018
15-0112.062014Standard Service Door (ESD10)Up to 14'-5" Wide80 FPSX65XJuly 9, 2020
15-0112.072014Standard Service Door (ESD10)Up to 14'-5" Wide50 FPSX65XJuly 9, 2020
15-0318.082014Insulated Service Door (ESD20 & ESD30)Up to 14'-5" Wide80 FPSX120XJuly 9, 2020
15-0318.092014Insulated Service Door (ESD20 & ESD30)Up to 25'-5" Wide80 FPSX65XJuly 9, 2020
15-0318.102014Standard Service Door (ESD10)Up to 25'-5" Wide80 FPSX65XJuly 9, 2020
15-0504.032014Insulated Service Door (ESD20 & ESD30)Up to 12'-5" Wide50 FPSX65XJuly 9, 2020
15-0504.042014Insulated Service Door (ESD20 & ESD30)Up to 12'-5" Wide80 FPSX65XJuly 9, 2020

Florida Building Code (FBC)

FBC EditionFL #Product
2014FL14636-R4Roll-Up Exterior Door Assemblies (ESD10, ESD20 & ESD30)
2014FL17419-R1Roll-Up Exterior Door Assemblies (ESD10, ESD20 & ESD30)
2017FL17419-R2Roll-Up Exterior Door Assemblies (ESD10, ESD20 & ESD30)
2017FL19074-R1Roll-Up Exterior Door Assemblies (ESC10)

Texas Department of Insurance (TDI)

Manufacturer/DistributorProduct(s)Report Number
Cornell Iron Works, Inc. CP0020 Non-Insulated Steel Roll-up Doors (ESD10)GDR-30 (PDF) 
Cornell Iron Works, Inc. CP0001/CP0651 Insulated Steel Roll-up Doors (ESD20 & ESD30)GDR-31 (PDF) | Drawings
Cornell Iron Works, Inc.  CP0020 Steel Rolling Doors (ESD10)GDR-57 (PDF)
Cornell Iron Works, Inc.  CP0001/CP0651 Rolling Doors (ESD10)GDR-58 (PDF) | Drawings

Back to Top
Seismic Performance Calculations per ASCE 7-10
Cornell can provide project specific seismic calculations for all Service (ESD10), Thermiser® (ESD20 & ESD30), Fire (ERD10) and Firemiser® (ERD20) doors that are mounted Face of Wall or Between Jambs to steel or masonry. Seismic performance validation is per ASCE 7-10.

Back to Top
Acoustical Testing Reports - Sound Transmission Class (STC) Rating

Thermiser (ESD20) Insulated Rolling Door has a Sound Transmission class rating of up to 30 for the curtain and up to 18 for the complete, operable assembly. Tested according to ASTM E90.*

Thermiser Max (ESD30) Insulated Rolling Door has a Sound Transmission class rating of up to 30 for the curtain and up to 22 for the complete, operable assembly. Tested according to ASTM E90.*

TranZform Sound (ESP20) achieved an STC 45 when tested to today’s ASTM E90 standards by an independent laboratory. TranZform Space (ESP10) achieved STC 30.

*If an STC of 32 is desired, additional options are required. Please consult the factory for details. 

Back to Top