Operator Information


Service Doors / Insulated Doors / Rolling Grilles / Sentry Gate®4 Grilles

Note: UL325 Standard requires covering moving components of all exposed motors mounted at or below 8 feet in height. Cornell's UL325 Compliance Recommendation

Sensing Edges Options for Cornell Doors Document

Models MG: cULus listed, industrial duty gear head operator rated for a maximum of 20 cycles per day. Totally Enclosed Non-Ventilated (TENV) motor. Factory pre-wired motor control terminals. Maintenance free, solenoid actuated brake. Motor mounted interlock available to 1/2 HP. Auxiliary manual chain hoist for emergency operation or provisions for auxiliary push-up operation. Auxiliary chain hoist safely cuts operator power when engaged: just pull to operate. Overload protection. Lubricated, heavy-duty gears. Compact operator / mounting configuration. Fully adjustable, driven linear screw type cam limit switch mechanism.

Cycle Rating: rated for a maximum of 20 cycles per day.
HP: 1/3, 1/2, and 3/4
Volts: 115, 208/230, 460 and 575.
Available for all rolling doors, insulated doors, rolling grilles and SentryGate 4’s up to 3/4 HP rating that will routinely cycle up to 20 times per day.

Model MG Data Sheet

Model MG Installation Instructions \ Wiring Diagrams

Model SG: cULus listed, super duty gear head operator designed for continuous use. Totally Enclosed Fan Cooled (TEFC) motor. Factory pre-wired motor control terminals. Maintenance free, solenoid actuated brake. Auxiliary manual chain hoist for emergency operation provided up to 2 HP as standard. Auxiliary chain hoist automatically engages when motor is not energized: just pull to operate. Overload protection. Lubricated, heavy-duty gears. Compact operator / mounting configuration. Fully adjustable, driven linear screw type cam limit switch mechanism.

Cycle Rating: designed for continuous use.
HP: 1/2, 3/4, 1, 1 1/2, 2, 3, 5 and 7 1/2 HP operators are available.
Voltage: 115, 208/230, 460 and 575. Sizes above 3/4 HP should be 3 phase.
Recommended for all rolling doors, insulated doors, rolling grilles and SentryGate 4’s, including units requiring high cycle operation (more than 20 cycles per day).
Model SG Data Sheet

Model SG Installation Instructions \ Wiring Diagrams

Tube Motors: cULus recognized, 110 Volts, 1 Phase. Provided complete with electric tube motor, maintenance free electric brake, emergency manual crank hoist and control station. Motor is protected against overload with an auto-reset thermal sensing device. Operator shall be equipped with an emergency manual crank hoist assembly that safely cuts operator power when engaged. A disconnect chain shall not be required to engage or release the manual crank hoist. Operator shall be capable of 10-14 RPM. Fully adjustable, mechanical internal worm limit switch mechanism synchronizes the operator with the door.

Cycle Rating: rated for a maximum of 10 cycles per day.
Sizes: available for rolling grilles and SentryGate grilles for tight clearances or aesthetics with size limits based on unit curtain configuration and operator rating. Consult Cornell.
Volts: 110, 1 phase. 115 VAC power required.
Tube Motor Operator Data Sheet

Tube Motor Operator Installation Instructions


Counter Doors / SentryGate® 3

Note: UL325 Standard requires covering moving components of all exposed motors mounted at or below 8 feet in height. Cornell's UL325 Compliance Recommendation

Sensing Edges Options for Cornell Doors Document

Tube Motors: cULus recognized, 110 Volts, 1 Phase. Provided complete with electric tube motor, maintenance free electric brake, emergency manual crank hoist and control station(s). Motor is protected against overload with an auto-reset thermal sensing device. Operator shall be equipped with an emergency manual crank hoist assembly that safely cuts operator power when engaged. A disconnect chain shall not be required to engage or release the manual crank hoist. Operator shall be capable of 10-14 RPM. Fully adjustable, mechanical internal worm limit switch mechanism shall synchronize the operator with the door. The electrical contractor shall mount the control station(s) and supply the appropriate disconnect switch, all conduit and wiring per the overhead door wiring instructions.

Cycle Rating: rated for a maximum of 10 cycles per day.
Sizes: available for rolling grilles and SentryGate grilles for tight clearances or aesthetics with size limits based on unit curtain configuration and operator rating. Consult Cornell.
Volts: 110, 1 phase. 115 VAC power required.
Recommended for all counter doors and SentryGate 3 units within the above size limits.

Tube Motor Operator Data Sheet

Tube Motor Operator Installation Instructions

Models MG: cULus listed, industrial duty gear head operator rated for a maximum of 20 cycles per day. Totally Enclosed Non-Ventilated (TENV) motor. Factory pre-wired motor control terminals. Maintenance free, solenoid actuated brake. Motor mounted interlock available to 1/2 HP. Auxiliary manual chain hoist for emergency operation or provisions for auxiliary push-up operation. Auxiliary chain hoist safely cuts operator power when engaged: just pull to operate. Overload protection. Lubricated, heavy-duty gears. Compact operator / mounting configuration. Fully adjustable, driven linear screw type cam limit switch mechanism.

Cycle Rating: rated for a maximum of 20 cycles per day.
HP: 1/3, 1/2, and 3/4
Volts: 115, 208/230, 460 and 575.
Available for all counter doors and SentryGate 3 units above the size limits for tube motors

Model MG Data Sheet

Model MG Installation Instructions \ Wiring Diagrams

 


Fire Doors / Insulated Fire Doors / SmokeShield® Doors

Note: UL325 Standard requires covering moving components of all exposed motors mounted at or below 8 feet in height. Cornell's UL325 Compliance Recommendation


Download the M100 FireGard™ and FireGard™ Closing Systems for a full description of Cornell Fire Door Closing Systems.

M100 FireGard™ Closing Systems Data Sheet

M100 FireGard™ Electric Motor Operated Systems
Model FS, cULus listed, FM approved M100 system operator; part of a reliable, slow closing fire door system that never needs to be mechanically reset and features easy system testing at the floor level. Open drip-proof motor, removable without affecting setting of limit switches. Centrifugal governor. UL listed thermal overload protection. Solenoid brake. Planetary gearing capable of being driven backwards or forwards. Rotary limit switches. Transformer with 24 volt control secondary. All integral components pre wired to terminal block. Automatic closure activated by fusible link or central smoke / fire alarm system. Doors do not require a releasing device when activated by alarm signal. Doors shall be fail-safe and close upon power failure. Resetting of spring tension or mechanical dropouts is not required. Upon restoration of power, replacement of the fusible link or clearing of the alarm signal, doors shall immediately reset by opening with the push button.

HP: 1/3, 1/2, 3/4, 1 1/2, 2, 3, 5
Voltage: [115v single] [230v single] [208/230v three] [460v three] phase service

Recommended for all fire doors where the convenience of electric M100 FireGard Motor Operation is desired.

Optional F-BBU Battery Back-up System to M100 Model FS motor operators to add a four hour time of door open time in the event of a power failure. Can power local detectors and warning appliances. Allows for programming open/ close obstruction cycling should the sensing edge encounter a stationary obstruction in the opening during AC power alarm signal closing.

M100 FireGard™ Chain or Crank Operated Systems
Manual M100 system operators; part of a reliable, slow closing fire door system that never needs to be mechanically reset and features easy system testing and resetting. These compact chain and crank operator designs include a built-in, automatic reset release device for connection to a central alarm system or local detectors - no external release device is required. Units will close automatically upon alarm or power failure in excess of 10 seconds. Resetting spring tension or re-engaging the operator is not required. Operators safely stop the curtain in any position; will not excessively back wind. Accept 24 VDC or 115 VAC or 24 VAC power. UL 864 listing. 24 VDC output for close warning device.

Recommended for fire doors that do not require the daily operation convenience of a motor operator and that will have the required access to the hand chain or crank operator. Available for use on all counter fire doors and fire doors to 34' wide or 28' high. Crank units available for units less than 12' high. Chain or crank operation is not recommended for doors that will be used frequently.

View Cornell's M100 FireGard™ video

A full line of FireGard™ Closing Systems with simplified reset fire doors is also available. These systems close fire rated door without releasing spring tension or disengaging the operator drive mechanism. They are recommended for:openings not in a pedestrian thoroughfare, where connection to a central alarm system or local detectors is not required by local building officials, or where installation of fu si ble links, turnbuckles, chains and eyebolts to the face of both sides of the wall above the opening will not detract from the intended aesthetics of the opening.

FireGard™ Motor Operated Systems
Model FMG cULus listed, Totally Enclosed Non Ventilated gear head operator rated for units that normally cycle up to 20 times per day. Fire door system closing is activated by melting of fusible link. Average closing system speed is not less than 6 inches nor more than 24 inches per second. System reset procedure is to replace and reset fusible link.

HP: 1/3, 1/2, 3/4

Voltage: [115v single] [230v single] [208/230v three] [460v three] phase service
Available where the convenience of electric FireGard Motor Operation is desired in the above FireGard Closing System conditions for fire doors up to 225 square feet, insulated fire doors up to 165 square feet.

FireGard™ Chain or Crank Operated Systems
Combination hand chain or hand crank / controlled closing system operator including steel chain or removable hand crank, geared reduction unit and an electric wall mounted close control station. Fire door system closing is activated by melting of fusible link. Average closing system speed is not more than 12 inches per second. System reset procedure is to replace and reset fusible link.

Available for fire doors that do not require the daily operation convenience of a motor operator in the above FireGard closing system conditions and that will have the required access to the hand chain or crank operator. Available for use on all counter fire doors and fire doors to 34' wide or 28' high. Crank units available for units less than 12' high. Chain or crank operation is not recommended for doors that will be used frequently.

Fire Door Closing System Accessories

Sensing Edges Options for Coiling Doors Document

Specialty Operators and Push Up Operation are available. These conventional systems release spring tension and require mechanical resetting by a trained door system technician.

 


Counter Fire Doors / Integral Frame Units / SmokeShield® Counter Fire Doors

Note: UL325 Standard requires covering moving components of all exposed motors mounted at or below 8 feet in height. Cornell's UL325 Compliance Recommendation

Sensing Edges Options for Cornell Doors Document

M100 FireGard™ Tube Motors: cULus recognized, 115 Volts, 1 Phase, 60 Hertz. Provided complete with electric tube motor, maintenance free electric brake, emergency manual crank hoist and control station(s). Motor is protected against overload with an auto-reset thermal sensing device. Operator is equipped with an emergency manual crank hoist assembly that safely cuts operator power when engaged. A disconnect chain is not required to engage or release the manual crank hoist. Operator is capable of 10-14 RPM. Fully adjustable, mechanical internal worm limit switch mechanism synchronizes the operator with the door. Automatic closure is activated by a local smoke/fire detector or a central smoke/fire alarm system. Doors maintain an average closing speed of not more than 12” per second during automatic closing. When automatic closure is activated, electric sensing edge and push button are inoperable. Doors are fail-safe and close upon power failure. Resetting of spring tension or mechanical dropouts is not required. Upon restoration of power and/or clearing of the alarm signal, doors immediately reset by opening with the push button.

Cycle Rating: rated for a maximum of 10 cycles per day.
Sizes: recommended for all counter fire doors to a maximum width of 14' 0", a maximum height of 9' 0" with a maximum total of 90 square feet. Available for counter fire doors with integral frame and sill up to 14' 0" wide by 6' 0" high.
Volts: 110, 1 phase. 115 VAC power required.
Recommended for all counter fire door products within the above size limits.

Download M100 FireGard™ Tube Motor Operator Data Sheet

Also see M100 FireGard™ Operating systems and FireGard™ Operating Systems above.


Side Folding Grilles / Side Folding Closures

Push-Pull operation only.


TranZform®

TranZform Fire - Motor operation provided as standard for controlled automatic closing with emergency exit capability and ease of testing.

TranZform Space - Manual push/pull operation standard. Consult factory for motor operated units.

TranZform Space - Manual push/pull operation.